How much electricity commercial solar makes in the UK
We asked PVGIS, the European Commission Joint Research Centre's solar tool, for the yearly output of 1 kW of panels in seven UK cities, with its default allowance of 14% for system losses (PVGIS 5.3). Multiply by the size of your system in kW for a rough yearly figure.
Yearly output per kW of panels by city, PVGIS 5.3, queried 2 November 2026
| City | South, 35° tilt | South, 10° tilt | East-west, 10° tilt |
|---|---|---|---|
| Plymouth | [object Object] kWh | [object Object] kWh | [object Object] kWh |
| Cardiff | [object Object] kWh | [object Object] kWh | [object Object] kWh |
| London | [object Object] kWh | [object Object] kWh | [object Object] kWh |
| Birmingham | [object Object] kWh | [object Object] kWh | [object Object] kWh |
| Newcastle | [object Object] kWh | [object Object] kWh | [object Object] kWh |
| Manchester | [object Object] kWh | [object Object] kWh | [object Object] kWh |
| Glasgow | [object Object] kWh | [object Object] kWh | [object Object] kWh |
The east-west figure is the average of an east-facing and a west-facing panel at 10 degrees, the usual layout on flat roofs. PVGIS uses satellite radiation data for 2005 to 2023 (SARAH3) and terrain shading; it does not know about your trees, chimneys or neighbouring buildings.
Summer, winter and the year's total
Output per kW by month, Birmingham, south facing at 35°, PVGIS 5.3
| Month | kWh per kW |
|---|---|
| Jan | 37 |
| Feb | 52 |
| Mar | 84 |
| Apr | 108 |
| May | 117 |
| Jun | 117 |
| Jul | 118 |
| Aug | 106 |
| Sep | 90 |
| Oct | 63 |
| Nov | 42 |
| Dec | 33 |
In Birmingham, December gives about 33 kWh per kW and June about 117: winter output is roughly a quarter of summer's. Across the seven cities, between 67% and 72% of the year's output comes from April to September, and the further north, the bigger the swing (PVGIS).
- Size against the whole year: A system sized to use everything in December will export a lot in June
- Seasonal businesses: Farms at harvest, holiday parks and cooling-heavy sites line up well with summer output
- Winter-heavy businesses: Heating-led or winter-peaking sites get less from solar when they need most
Orientation, tilt and shading
South facing at around 35 degrees gives the most per kW in the UK of the layouts we checked. Laying panels at 10 degrees on a flat roof cost about 10% of the yearly output in every city, and an east-west layout about 17 to 18% (PVGIS). Shading is often a bigger loss than either, because one shaded panel can pull down a whole string unless the system uses module-level electronics.
For pitched roofs, the direction is fixed. A south-west or south-east roof still produces well; north-facing pitched roofs rarely make sense. See flat roof solar for ballasted and fixed layouts.
East-west layouts
East-west arrays on flat roofs face half the panels each way at a low angle, back to back. They make less per kW, but:
- More panels on the same roof: Low rows need little gap between them, so more kW fits on the roof
- Flatter daily curve: Output starts earlier in the morning and lasts later into the afternoon, matching a working day
- Lower wind loading: Low, back-to-back rows sit closer to the roof
Example: A 50 kW system in Birmingham, three ways (PVGIS 5.3)
South at 35°: 50 × 968 = about 48,400 kWh a year
South at 10°: 50 × 875 = about 43,750 kWh a year
East-west at 10°: 50 × 800 = about 40,000 kWh a year
If east-west fits 60 kW on a roof that takes 50 kW facing south, it makes about the same: 60 × 800 = 48,000 kWh
Example only, before shading. Your installer's design for your roof is the figure to use.
How your estimate is worked out
An MCS certified installer records an estimated system performance in the installation paperwork set out in the MCS standard MIS 3002 (MCS). Many designers also model the roof in PVGIS or design software. Ask how shading was assessed, what losses were assumed and which panels and inverters the figure is based on.
The yearly total only matters if you use it. Laid over twelve months of your half-hourly data, it shows how much the business uses itself and how much is exported. See how much solar you need, system sizes and payback.
Note: Estimates for an unshaded array. Real output depends on your site, the equipment and the weather in a given year.
Sources
PVGIS 5.3 was queried on 2 November 2026 (1 kWp, 14% losses, SARAH3 radiation 2005 to 2023). The MCS standard was read on 2 November 2026.
Frequently asked questions
How much electricity does commercial solar produce in the UK?
Roughly 850 to 1,120 kWh a year for every kW of panels facing south at 35 degrees, depending on where you are, using PVGIS, the European Commission's solar tool, with its default 14% system losses. Glasgow is at the low end of that range and Plymouth at the top. Flatter or east-west arrays make less per kW.
How much does a 50 kW solar system produce?
About 43,000 to 56,000 kWh a year if it faces south at 35 degrees, from Glasgow to Plymouth on PVGIS figures. In Birmingham the figure is about 48,000 kWh. A flat or east-west layout makes less per kW, and shading reduces it further. Your installer's estimate for your roof is the one to rely on.
Do solar panels work in winter in the UK?
Yes, but they make much less. In Birmingham, PVGIS gives a south-facing panel about 33 kWh per kW in December against about 117 in June, roughly a quarter. Across the UK cities we checked, between 67% and 72% of the year's output comes from April to September.
Are east-west solar panels worth it?
Often, on flat and low-pitched commercial roofs. An east-west array at 10 degrees makes less per kW than south-facing panels (about 800 kWh per kW in Birmingham, against 968 at 35 degrees south), but it fits more panels on the same roof and spreads output across the morning and afternoon, which can suit a business's working day.
How is a solar output estimate worked out?
From the system size, the site's location, the direction and tilt of the panels and any shading. MCS installers record an estimated system performance in the installation paperwork set out in the MCS standard MIS 3002; many designers model it in PVGIS or design software. Ask how shading was assessed and what losses were assumed.
Related pages
- Sizing your systemHow to size commercial solar from consumption data, roof area and grid limits, with typical rules of thumb, a worked illustrative example and notes on batteries and future loads.
Smart Export GuaranteeHow SEG export payments work for business solar in Great Britain, who is eligible, what accreditation and metering you need, and how much export adds to the case.
Solar paybackA worked payback example for a 100 kWp system, the factors that move the result most, the effect of tax relief, and a calculator to try your own figures.
Battery storageWhen a commercial battery pays: storing surplus solar, time of use tariffs, peak shaving, sizing from half-hourly data, illustrative costs, safety and siting.