The three scopes in one table
The GHG Protocol Corporate Standard sorts a company's greenhouse gas emissions into three scopes (GHG Protocol Corporate Standard):
| Scope | GHG Protocol definition | Typical examples for a UK business |
|---|---|---|
| Scope 1 | Direct emissions "from sources that are owned or controlled by the company" | Gas boilers and furnaces, owned or leased vans and cars, forklifts, generators, refrigerant leaks |
| Scope 2 | Emissions "from the generation of purchased electricity consumed by the company" | Electricity bought from the grid; purchased heat, steam or cooling |
| Scope 3 | All other indirect emissions, which "occur from sources not owned or controlled by the company" | Goods and services you buy, deliveries, waste, business travel, staff commuting, use of the products you sell |
The standard says companies "shall separately account for and report on scopes 1 and 2 at a minimum", and calls Scope 3 "an optional reporting category". Its separate Corporate Value Chain (Scope 3) Standard, released in 2011, splits Scope 3 into 15 categories, upstream and downstream of your own operations (GHG Protocol Scope 3 Standard).
A simple test: if you burn it, it is Scope 1. If you buy it as electricity or heat, it is Scope 2. If someone else burns it to make, move or dispose of something for you, or your customers burn it using what you sold them, it is Scope 3.
The 15 Scope 3 categories
| Upstream (what comes in) | Downstream (what goes out) | ||
|---|---|---|---|
| 1 | Purchased goods and services | 9 | Downstream transportation and distribution |
| 2 | Capital goods | 10 | Processing of sold products |
| 3 | Fuel and energy related activities (not in Scope 1 or 2) | 11 | Use of sold products |
| 4 | Upstream transportation and distribution | 12 | End of life treatment of sold products |
| 5 | Waste generated in operations | 13 | Downstream leased assets |
| 6 | Business travel | 14 | Franchises |
| 7 | Employee commuting | 15 | Investments |
| 8 | Upstream leased assets |
For most small and mid-sized businesses, category 1 (what you buy) is the largest. Category 3 is easy to miss: it covers the emissions from producing the fuels and electricity you use and the electricity lost in the grid on the way to you, which the government publishes factors for.
What UK businesses actually have to report
| Who | What is asked | Where it comes from |
|---|---|---|
| Quoted companies | Global Scope 1 and Scope 2 emissions and underlying energy use; Scope 3 voluntary but strongly encouraged where material | SECR, in the Directors' Report |
| Large unquoted companies and LLPs | UK Scope 1 and 2 emissions from UK energy use (at least electricity, gas and transport fuel), plus business travel in rental cars or employees' own vehicles where the company buys the fuel; other Scope 3 voluntary | SECR, in the Directors' Report or an Energy and Carbon Report |
| Suppliers bidding for central government contracts over £5 million a year | Scope 1, Scope 2 and five Scope 3 categories: 4, 5, 6, 7 and 9 | A carbon reduction plan under PPN 006 |
| Everyone else | Nothing by law, but larger customers increasingly ask suppliers for their figures | Customer questionnaires and tenders |
The SECR rows are from the government's environmental reporting guidance, which lists the business travel rule under Scope 3 and says "other Scope 3 emissions" are "voluntary, but strongly encouraged where this is a material source of emissions" (GOV.UK environmental reporting guidance). A company that used 40,000 kWh or less in the period can state that it is a low energy user instead; our guide to solar and carbon reporting covers SECR's disclosures in full. PPN 006's technical standard names the five Scope 3 categories and says the footprint should follow the GHG Protocol Corporate Standard, converted "using the appropriate conversion factors published by the UK Government" (PPN 006 technical standard); see our guide to carbon reduction plans.
If you sell to a large company, your Scope 1 and 2 emissions are part of its Scope 3 (category 1 for goods and services). That is why supplier questionnaires ask for them, and why a figure that falls year on year helps in a tender.
How to work out Scope 1 and 2
The method is the same for every line: activity data (kWh, litres, miles) multiplied by the government's conversion factor for that year. The 2026 factors were published on 11 June 2026 and updated on 31 July 2026 (GOV.UK conversion factors 2026).
Common 2026 UK conversion factors, kg CO2e per unit
| Activity | Scope | Factor |
|---|---|---|
| Natural gas, per kWh (gross CV) | 1 | 0.18231 |
| Diesel (average biofuel blend), per litre | 1 | 2.58354 |
| UK grid electricity, per kWh | 2 | 0.13096 |
| Electricity lost in transmission and distribution, per kWh | 3 (category 3) | 0.01299 |
| Producing the grid electricity (well to tank), per kWh | 3 (category 3) | 0.03682 + 0.00359 |
| Producing the natural gas (well to tank), per kWh | 3 (category 3) | 0.03021 |
Your gas and electricity bills give the kWh; fuel cards or receipts give the litres. Use the factor for the reporting year, and keep the kWh and litres alongside the tonnes: the grid electricity factor changes every year, so tonnes can move even when your use does not.
Worked example: a manufacturer's Scope 1 and 2, before and after solar
Take the illustrative manufacturer used across this site: it uses 300,000 kWh of electricity a year. Assume, for illustration, that it also burns 400,000 kWh of gas for heating and process, and its own vans use 20,000 litres of diesel. It installs a 100 kWp rooftop system at an illustrative £900 per kWp, generating about 90,000 kWh a year, 80% used on site.
| Before solar | With 100 kWp of solar | |
|---|---|---|
| Scope 1: gas, 400,000 kWh × 0.18231 | 72.9 tCO2e | 72.9 tCO2e |
| Scope 1: diesel, 20,000 litres × 2.58354 | 51.7 tCO2e | 51.7 tCO2e |
| Scope 2: grid electricity × 0.13096 | 39.3 tCO2e (300,000 kWh) | 29.9 tCO2e (228,000 kWh) |
| Scope 1 and 2 total | 163.9 tCO2e | 154.5 tCO2e |
| Scope 3, category 3, from the electricity × 0.0534 | 16.0 tCO2e | 12.2 tCO2e |
How the figures are worked out:
- Scope 1: 400,000 × 0.18231 = 72,924 kg; 20,000 × 2.58354 = 51,671 kg. Solar does not touch either.
- Scope 2: 300,000 × 0.13096 = 39,288 kg. With solar, 72,000 kWh is no longer bought, so 228,000 × 0.13096 = 29,859 kg: about 9.4 tonnes less, a 24% cut in Scope 2 and about 6% of Scopes 1 and 2 together.
- Scope 3, category 3: the three electricity factors (0.01299 + 0.03682 + 0.00359 = 0.0534 kg per kWh) fall with the electricity you buy: 16,020 kg before, 12,175 kg after.
- The bill: 72,000 kWh at an illustrative 24p is £17,280 a year, plus 18,000 kWh exported at 5p, about £900. At about £90,000 that is a simple payback of roughly 5 years before tax relief; see how payback is worked out and capital allowances.
What the example shows: on a site that burns gas and runs vans, Scope 1 can be much bigger than Scope 2, and solar cuts only the electricity part. Moving heat or vehicles onto electricity moves those emissions from Scope 1 into Scope 2, where the grid factor is lower and your own solar can supply some of it. The 18,000 kWh exported is not deducted from Scope 2; it can be reported separately.
Ways to cut each scope
- Scope 1: fix heating controls and insulation, service boilers, plan for heat pumps or electric process heat, and move vans to electric as they come up for renewal. Our guide to cutting business energy costs puts the cheap measures in order.
- Scope 2: use less electricity, then generate your own. On-site solar you use cuts both the location-based and the market-based figure, because you buy fewer kWh. A green tariff can lower only the market-based figure; see REGO certificates.
- Scope 3: start with the categories you can measure: waste, business travel and commuting, deliveries, then ask your biggest suppliers for their own Scope 1 and 2 figures.
A free site survey works out what rooftop solar would do to your own Scope 2 figure and your bill, from your half-hourly data.
Note: General information, not reporting advice. Check which version of the GHG Protocol and the conversion factors your report uses, and confirm the treatment of exported electricity, PPAs and certificates with whoever prepares your figures.
Sources
Read on 25 November 2026.
- GHG Protocol: A Corporate Accounting and Reporting Standard (revised edition), chapter 4
- GHG Protocol: Corporate Value Chain (Scope 3) Standard
- GOV.UK: Environmental reporting guidelines including SECR (March 2019)
- GOV.UK: Greenhouse gas reporting conversion factors 2026 (updated 31 July 2026)
- GOV.UK: PPN 006 technical standard for completion of carbon reduction plans (updated 10 July 2025)
Frequently asked questions
What is the difference between Scope 1, 2 and 3 emissions?
Scope 1 is emissions from fuel your business burns in sources it owns or controls, such as gas boilers and company vans. Scope 2 is emissions from generating the electricity, heat or steam you buy. Scope 3 is all other indirect emissions in your value chain, such as the goods you buy, deliveries, waste, travel and the use of products you sell.
Is Scope 3 reporting mandatory in the UK?
Mostly not. Under SECR, quoted companies must report Scope 1 and 2 and are strongly encouraged to report material Scope 3. Large unquoted companies must include business travel in rental cars or employees' own vehicles where they buy the fuel. Suppliers bidding for central government contracts over £5 million a year must report five Scope 3 categories in a carbon reduction plan.
How do I calculate my Scope 2 emissions?
Multiply the kWh of electricity you bought in the year by the government's conversion factor for that year. For 2026 the UK grid factor is 0.13096 kg CO2e per kWh, so 300,000 kWh is about 39.3 tonnes. That is the location-based figure. A market-based figure uses your supplier's factor or certificates instead, and many reporters show both.
Do solar panels reduce Scope 1 or Scope 2 emissions?
Scope 2. Solar electricity you use on site is electricity you no longer buy, so your Scope 2 figure falls in both the location-based and market-based methods. It also cuts the Scope 3 category 3 emissions linked to that electricity. It does not change Scope 1 unless you also move gas heating or vehicles onto electricity.
Why are my customers asking for my Scope 1 and 2 emissions?
Because your emissions are part of their Scope 3. A large company reporting its value chain counts the emissions of the goods and services it buys, so it asks its suppliers for their figures. Having your Scope 1 and 2 worked out, and a plan to reduce them, can help in tenders and supplier reviews.
Related pages
- Solar and carbon reportingHow on-site solar affects Scope 2 emissions, location-based and market-based reporting, SECR, carbon reduction plans, supplier questionnaires and REGOs, in plain terms.
- Carbon reduction plansBidders for larger central government contracts must publish a carbon reduction plan; on-site solar cuts the scope 2 emissions it reports.
- REGO certificatesWhat a REGO is, how suppliers and businesses use them, what a REGO-backed green tariff does and does not change, and a worked comparison with rooftop solar.
- ESOSESOS is a mandatory energy assessment for large UK undertakings every four years; solar is one of the measures an audit can lead to.
- Renewable energy for businessOn-site solar, storage, off-site PPAs and green tariffs compared, with what each does for cost and for reported emissions.
Solar paybackA worked payback example for a 100 kWp system, the factors that move the result most, the effect of tax relief, and a calculator to try your own figures.